Educational article
S, I, R and MIC
MIC is the lowest concentration inhibiting visible growth under specified conditions. EUCAST S means susceptible at standard exposure, I susceptible with increased exposure, and R a high likelihood of failure even with…
Overview
MIC is the lowest concentration inhibiting visible growth under specified conditions. EUCAST S means susceptible at standard exposure, I susceptible with increased exposure, and R a high likelihood of failure even with increased exposure. I must not be merged with R.
Biology and practical meaning
MIC is interpreted with the clinical breakpoint for the organism–agent pair. On 6 October 2026, bacterial EUCAST tables v16.1 were checked, effective from 24 June 2026. Simply comparing two drugs’ MIC numbers does not establish superiority; site and exposure also matter.
| Concept | Meaning |
|---|---|
| S | Susceptible at standard exposure. |
| I | Susceptible with increased exposure. |
| R | High likelihood of failure even with increased exposure. |
Traceability and result quality
The diagnostic pathway includes specimen selection and collection, analysis, verification and reporting. A sound analytical method cannot automatically correct mislabelling or an unsuitable sampling site. Collection and transport conditions follow the receiving laboratory’s instructions.
Internal quality control monitors the process; external assessment compares performance with independent evaluation. These approaches complement each other. Documentation, training, equipment maintenance and management of nonconformities also belong to the quality system.
When a deviation occurs, establish its cause and scope: which results may be affected, whether repetition or an amended report is needed, and how recurrence will be prevented. Repeating a test without identifying the cause does not always solve the problem. A report should make the specimen, method, result and limitations clear. A test not performed is not a negative test, and a technically uncertain result cannot automatically become a clinical category. Current institutional procedures take precedence over universal advice from a brief reference article.
Current source edition
The current bacterial EUCAST tables checked on 6 October 2026 are v16.1, effective from 24 June 2026. Retain the version with the result: a revised breakpoint can change a category without changing the measured MIC.
Sources
Read next
Educational material from AMR Atlas. Does not replace clinical guidance or laboratory procedures.